Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38616156

RESUMO

This dental technique article updates the 3-dimensional (3D) virtual patient digital workflow by introducing the space-time information acquired with jaw tracking motion. The direct digital procedure involved scanning the interim prostheses, creating virtual casts, and transferring the digital facebow, virtual articulation, and jaw-tracking motion. All 3D files and records from the intraoral scanner, cone beam computed tomography, extraoral scanner, and jaw tracking motion were superimposed using existing teeth as the connecting link in all data sets and adopting the best-fit alignment. The main advantages of the technique were creating a 4-dimensional virtual patient and standardizing the introduction of clinical space-time information (the fourth dimension) beyond the static condition.

2.
J Mech Behav Biomed Mater ; 152: 106451, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310814

RESUMO

The objective of this work is to analyse the performance of clear aligners made of thermoplastic materials. Within this framework, the damage evolution stages and damage states of the aligners at different cycles of the compressive loading are evaluated using the Acoustic Emission (AE) technique. Three different clear aligner systems were prepared: thermoformed PET-g (polyethylene terephthalate glycol) and PU (polyurethane), and additively manufactured PU. Cyclic compression tests are performed to simulate 22500 swallows. The mechanical results show that the energy absorbed by the thermoformed PET-g aligner remains stable around 4 Nmm throughout the test. Although the PU-based aligners show a higher energy absorption of about 7 Nmm during the initial phase of the cyclic loading, this gradually decreases after 12500 cycles. The time-domain based, and frequency-based parameters of the stress wave acoustic signals generated by the aligners under compression loading are used to identify the damage evolution stages. The machine learning-based AE results reveal the initiation and termination of the different damage states in the aligners and the frequency-based results distinguish the different damage sources. Finally, the microscopy results validated the damage occurrences in the aligners identified by the AE results. The mechanical test results indicate that the thermoformed PET-g has the potential to match the performance and requirements of the dentistry of the popular Invisalign (additively manufactured PU). The AE results have the potential to identify at which cycles the aligners may start losing their functionality.


Assuntos
Acústica , Aparelhos Ortodônticos Removíveis , Fenômenos Físicos , Microscopia , Poliuretanos
3.
Cranio ; : 1-8, 2023 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-37545185

RESUMO

OBJECTIVE: The Mandibular Advancement Device (MAD) is actually recommended for the treatment of Obstructive Sleep Apnea (OSA) with mild or moderate severity. The present study evaluated the effects of a fully customizable MAD-type device (It Makes You Sleep, IMYS), in patients with moderate-to-severe OSA. METHODS: Twenty-nine patients (15 men and 14 women; mean age 62, SD ±10 years) were retrospectively enrolled. Home Sleep Apnea Testing ;(HSAT) was performed for all patients at baseline (T0) and after three months (T1) of IMYS therapy. The analyzed respiratory parameters were: Apnea-Hypopnea Index (AHI), Oxygen Desaturation Index (ODI), Minimum Oxygen Saturation (minSO2) and Medium Oxygen Saturation (medSO2). RESULTS: From T0 to T1, a significant reduction of AHI and ODI was reported, as well as a significant increase of minSO2 and medSO2. CONCLUSION: The IMYS device could be an effective MAD appliance for treating moderate-to-severe OSA.

4.
J Dent ; 135: 104583, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37331577

RESUMO

OBJECTIVES: The aim of this study was to clinically evaluate the accuracy of a digital axiographic recording system in tracing the sagittal condylar inclination. METHODS: An axiographic examination that records the sagittal condylar path during protrusive/retrusive movement was performed on ten patients. Each subject was registered five different times by two different systems: 1) the Cadiax Gamma Diagnostic 4 computerized system as the control; 2) the Zebris Jaw Motion Analyser+  Optic System as the tested digital axiographic recording system. The records obtained allow to calculate the kinematic terminal transverse horizontal axis and the sagittal condylar inclination (SCI) at 3 and 5 mm along the pro-retrusive path. A linear mixed model was used to analyze if there was a statistically significant difference between the two systems. RESULTS: The mean left SCI value recorded by Zebris system were 49.81 ± 10.64° at 3 mm, 48.10 ± 11.04° at 5 mm, while the values recorded by Gamma system were 55.16° at 3 mm, 52.18° at 5 mm. The mean right SCI value recorded by Zebris system were 54.53 ± 10.26° at 3 mm, 51.85 ± 8.55° at 5 mm, while the values recorded by Gamma system were 49.68° at 3 mm, 48.23° at 5 mm. Linear mixed model showed no significant statistical difference between the two systems. CONCLUSIONS: Based on preliminary results, the Zebris Jaw Motion Analyzer+ Optic System demonstrates comparable accuracy to the Cadiax Gamma Diagnostic 4 when measuring sagittal condylar inclination. CLINICAL SIGNIFICANCE: The digital axiographic recording system enables to evaluate sagittal condylar inclination and to adjust virtual articulators in a digital workflow.


Assuntos
Côndilo Mandibular , Movimento , Humanos , Côndilo Mandibular/diagnóstico por imagem , Registro da Relação Maxilomandibular/métodos , Articuladores Dentários , Fenômenos Biomecânicos
5.
Cranio ; : 1-8, 2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35171757

RESUMO

OBJECTIVE: The mandibular advancement device (MAD) is currently suggested in patients with mild to moderate obstructive sleep apnea (OSA). This study investigated the effects of a new fully customizable MAD-type device called, "It Makes You Sleep" (IMYS), in patients with mild to moderate OSA. METHODS: Sixteen patients (14 men and 2 women; mean age 62; SD ± 11 years) were retrospectively enrolled. Each patient received home sleep apnea testing (HSAT) at baseline (T0) and after three months (T1) of IMYS treatment. The Apnea-Hypopnea Index (AHI), the Oxygen Desaturation Index (ODI), the Minimum Oxygen Saturation (minSO2) and the Medium Oxygen Saturation (medSO2) were analyzed. RESULTS: From T0 to T1, the IMYS treatment showed a significant reduction of AHI and ODI and a significant increase of minSO2 and medSO2. CONCLUSION: The IMYS appliance is an effective device for treating mild or moderate OSA.

6.
Dent J (Basel) ; 11(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36661545

RESUMO

The purpose of the present study was to evaluate: (i) maxillary occlusal plane changes after clear aligners therapy with a 3D measurement technique; and (ii) as a secondary outcome, if such changes were correlated to the patient's 1axilla-mandibular divergence. 3D maxillary models of 32 patients (7 males and 25 females; mean age 22.3 +/− 3.4 year) treated with clear aligners were analyzed. The angle (α) between a reference palatine plane and a maxillary occlusal plane was measured. Five angular cephalometric measurements (NSL/MP; PP-OP; OP-MP; PP-MP; PFH/AFH%) were performed and related to Δα. The subjects were further divided into three groups according to facial divergence. After aligner treatment, Δα increased in hyperdivergent patients and decreased in hypodivergent patients (p < 0.05). Δα showed a significant positive correlation with NSL/MP (rho = 0.44) and negative correlation with PFH/AFH% (rho = −0.53). Aligners treatment produced a counterlockwise rotation of the maxillary occlusal plane, even if this rotation occurs differently depending on divergence.

7.
J Prosthet Dent ; 127(3): 398-403, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33317830

RESUMO

The virtual articulator is a tool that reproduces the relationship between the jaws in a virtual environment. The purpose of this clinical report was to describe a completely digital protocol starting from the virtual articulator mounting to developing static and dynamic occlusion in a complex prosthetic rehabilitation.


Assuntos
Articuladores Dentários
8.
J Clin Exp Dent ; 13(6): e594-e600, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34188766

RESUMO

BACKGROUND: Maxillary expansion is a common orthodontic procedure that could have a positive effect also on airway patency. The aim of the present study was to evaluate the long-term effects of rapid maxillary expansion (RME) on nasopharyngeal area and cranio-cervical angulation in growing patients, compared to controls treated with a function-generating bite appliance (FGB). MATERIAL AND METHODS: Sixty patients aged 6-14 consecutively treated with RME or FGB were selected retrospectively and divided into two groups. Lateral cephalograms taken before and after treatment were retrieved, and the nasopharyngeal area, delimited superiorly by a sella-posterior nasal spine (PNS) line and inferiorly by a basion-PNS line, and the cranio-cervical angulation were measured. RESULTS: The mean observation time was 17.6 ± 8 months. No differences were present between the two groups regarding age and gender. The nasopharyngeal area increased significantly in both groups after treatment, but with no statistically significant difference between them. The cranio-cervical angulation showed no differences within or between groups. CONCLUSIONS: Maxillary deficiency treatment with either RME or FGB was followed by a comparable increase in nasopharyngeal area. Key words:Rapid maxillary expansion, Airway, Nasopharyngeal area, Adenoid.

9.
Implant Dent ; 28(1): 91-98, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30640310

RESUMO

PURPOSE: To introduce a user-friendly protocol for implant-retained prosthetic rehabilitation of fully edentulous patients based on facial profile and the cephalometric intermaxillary relationship. MATERIALS AND METHODS: The prosthetic rehabilitation of edentulous patients with implants based on facial profile assessment protocol commences with a clinical and cephalometric analysis, followed by a preliminary projection to obtain a harmonious interarch relationship, eventually stabilized by the preplanned prosthesis. The protocol is divided into the following 5 phases: esthetic evaluation; cephalometric-occlusal assessment; surgery; provisionalization; and definitive prosthesis. Evaluation of patient's satisfaction from the treatment provided was performed through a preoperative and postoperative visual analogue scale scores. RESULTS: The patient was granted immediate function and superior esthetics at day 1 of the treatment. These results were re-evaluated on an interval of 18 months and continued to be stable. The overall treatment time was significantly reduced. CONCLUSION: Our recommended protocol gives the clinician a chance to grasp results beyond the offered by traditional protocols by using a wider perspective of rehabilitation, involving the patient's facial profile, thus fulfilling the integration of both occlusal and cephalometric parameters in a unified surgical-prosthetic approach.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Estética Dentária , Face/anatomia & histologia , Carga Imediata em Implante Dentário/métodos , Arcada Edêntula/reabilitação , Cefalometria , Planejamento de Prótese Dentária , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente
10.
Biol Blood Marrow Transplant ; 22(10): 1758-1764, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27349920

RESUMO

The use of granulocyte colony-stimulating factor (G-CSF) primed bone marrow (G-BM) has been recently considered as an alternative to mobilized hematopoietic stem cells from peripheral blood (G-PB), especially in the haploidentical transplant setting. The purpose of this study was to compare the effect of in vivo G-CSF priming on BM and PB hematopoietic, mesenchymal (MSC), and immune cells. Forty healthy donors undergoing BM harvest for haploidentical transplant were given subcutaneous recombinant human G-CSF for 7 days. BM and PB samples were harvested on days -7 and 0. The hematopoietic stem/progenitor cells increased significantly after G-CSF priming in both BM and PB with a selective rise of BM CD34(+)CD38(-) cell subset. A striking enhancement of the mesenchymal progenitors was detected in G-BM. CD3(+), CD4(+), CD8(+), and CD19(+) cell fractions; the naive CD4(+) and CD8(+) subpopulations; and natural killer and regulatory T cells increased in G-BM, whereas only slight changes were detected in PB. Myeloid dendritic cells (DC1) were significantly up-regulated in both G-BM and G-PB, whereas DC2 increased only in G-BM. In conclusion, our results show substantial differences in the biologic effects exerted by G-CSF at BM and PB levels on hematopoietic cells and immune cell fractions. Furthermore, the impressive rise of MSC progenitors in G-BM might also be relevant to provide MSCs for several clinical use.


Assuntos
Medula Óssea/efeitos dos fármacos , Fator Estimulador de Colônias de Granulócitos/farmacologia , Células-Tronco de Sangue Periférico/efeitos dos fármacos , Doadores de Tecidos , Adulto , Idoso , Células Dendríticas/efeitos dos fármacos , Feminino , Voluntários Saudáveis , Células-Tronco Hematopoéticas/efeitos dos fármacos , Humanos , Sistema Imunitário/citologia , Sistema Imunitário/efeitos dos fármacos , Células Matadoras Naturais/efeitos dos fármacos , Masculino , Células-Tronco Mesenquimais/efeitos dos fármacos , Pessoa de Meia-Idade , Linfócitos T Reguladores/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...